3700 Series Windows

Let fresh air into the building through a storefront or curtainwall. Easily incorporated with Tubelite framing systems, let fresh air into the building with the 3700 Series windows.

These curtainwall rated windows have a frame depth of 2″ with a maximum size of 3’0″ x 5’0″ and mitred corners epoxied and crimped on an “L” shaped clip.

Standard and concealed project-out vent design and casement options are available. The concealed vent design is virtually invisible from the outside of the building with no visible frame. Screens are also available with frames finished to match the window.

3700 Series Windows

Let fresh air into the building through a storefront or curtainwall. Easily incorporated with Tubelite framing systems, let fresh air into the building with the 3700 Series windows.

These curtainwall rated windows have a frame depth of 2″ with a maximum size of 3’0″ x 5’0″ and mitred corners epoxied and crimped on an “L” shaped clip.

Standard and concealed project-out vent design and casement options are available. The concealed vent design is virtually invisible from the outside of the building with no visible frame. Screens are also available with frames finished to match the window.

3700 Series Windows

Let fresh air into the building through a storefront or curtainwall. Easily incorporated with Tubelite framing systems, let fresh air into the building with the 3700 Series windows.

These curtainwall rated windows have a frame depth of 2″ with a maximum size of 3’0″ x 5’0″ and mitred corners epoxied and crimped on an “L” shaped clip.

Standard and concealed project-out vent design and casement options are available. The concealed vent design is virtually invisible from the outside of the building with no visible frame. Screens are also available with frames finished to match the window.

VW3700 Vented Window Cutaway

VW3700

CW3700 Vented Window Cutaway

CW3700

CVW3700

EXAMPLES >

Calvary Church
Naperville, IL

Rossman Elementary
Cheyenne, WY

Calvary Church
Naperville, IL

3700 Series Windows VW3700 CVW3700 CW3700
Application Conventional Frame Concealed Vent Casement Type
Frame Joints Screw-spline Screw-spline Screw-spline
Window Joints Mitered, 2 Corner Keys, Lanced Stake & Silicone Mitered, 2 Corner Keys, Lanced Stake & Silicone Mitered, 2 Corner Keys, Lanced Stake & Silicone
Glass Thickness 1/4” & 1″ 1″ 1/4” & 1″
Face Width 2 3/8 2 3/8
Frame Depth 2″ 3 1/2 2″
Hardware 4-bar hinges, Cam lock 4-bar hinges, Cam lock 4-bar hinges, Cam lock, optional roto operator, 2-point egress lock, opening restrictor, egress pull-ring
Air Infiltration 0.10CFM/Ft2 @ 6.24psf 0.10CFM/Ft2 @ 6.24psf 0.10CFM/Ft2 @ 6.24psf
Static Water 12 PSF 12 PSF 12 PSF
AAMA/WDMA/CSA 101 I.5.2/
A440-08, NAFS Testing
CLASS CW-PG75
(60X36)-AP
CLASS CW-PG75
(61X38)-AP
CLASS CW-PG60
(36X60)-AP
Life Cycle Tested 2500 Cycles 2500 Cycles 2500 Cycles
CRF (AAMA 1503-2010) CRF-Value CRF-Value CRF-Value
U-Factor** U-Factor Table U-Factor Table U-Factor Table
Florida Approval
Non-Impact
FL15420 FL15420 FL15421
3700 Series Windows VW3700
Application Conventional Frame
Frame Joints Screw-spline
Window Joints Mitered, 2 Corner Keys, Lanced Stake & Silicone
Glass Thickness 1/4” & 1″
Face Width 2 3/8
Frame Depth 2″
Hardware 4-bar hinges, Cam lock
Air Infiltration 0.10CFM/Ft2 @ 6.24psf
Static Water 12 PSF
AAMA/WDMA/CSA 101 I.5.2/
A440-08, NAFS Testing
CLASS CW-PG75
(60X36)-AP
Life Cycle Tested 2500 Cycles
CRF (AAMA 1503-2010) CRF-Value
U-Factor U-Factor Table
Florida Approval
Non-Impact
FL15420

** U-Factor per NFRC 100: COG = 0.24 with warm edge spacer.

Guide Specification
Perimeter Sheet – DWG / PDF |
BIM Models
Maximum Sizes
Design Manual
Installation Instructions
Safety Data Sheets – SDS
Sample Warranty
Air-Water-Structural
CRF
Performance
Thermal AAMA 507
Thermal AAMA 1503
Thermal NFRC 102
Thermal NFRC Simulation
Guide Specification
Perimeter Sheet – DWG / PDF |
BIM Models
Maximum Sizes
Design Manual
Installation Instructions
Safety Data Sheets – SDS
Sample Warranty
Air-Water-Structural
CRF
Performance
Thermal AAMA 507
Thermal AAMA 1503
Thermal NFRC 102
Thermal NFRC Simulation
Guide Specification
Perimeter Sheet – DWG / PDF |
BIM Models
Maximum Sizes
Design Manual
Installation Instructions
Safety Data Sheets
Tubelite Sample Warranty
Air-Water-Structural
CRF
Performance
Thermal AAMA 507
Thermal AAMA 1503
Thermal NFRC 102
Thermal NFRC Simulation